APPLICATION & MAINTENANCE

Best results are obtained when Stat-Seal is applied to surfaces which are 60 o F. or warmer and in relative humidity conditions of between 40-65%. Remove old finish or sealer with #118 Eliminator Stripper. Vacuum up stripping solution and rinse the floor with clean water to remove any dissolved finish residue. When used as a base coat for #27 Stat-Coat, one or two coats are recommended depending on the porosity of the surface. When used as a sealer/finish on hard surfaces two or three coats will provide the optimum gloss and durability. Apply thin even coats, allowing Stat-Seal to dry, depending on humidity and temperature for approximately 30-45 minutes between coats. Allow two hours between the last coat of Stat-Seal and the first coat of Stat-Coat.

When used as a sealer/finish effective recoating may be achieved in the following manner. Vacuum the floor to remove any loose dirt or dust. Wash the floor with #137 Stat-Clean or a high quality synthetic neutral cleaner such as #127 Tops Neutral Cleaner, to remove dirt and soil. Apply thin even coats, allowing Stat-Seal to dry, for approximately 30 minutes before resumption of foot traffic.
Floor surfaces should be swept with an untreated mop daily to remove abrasive loose dirt and sand. Floors should be damp mopped with #137 Stat-Clean regularly, as needed, to remove soil, salt, and film deposits which can degrade the coatings conductive properties and gloss.
For optimum results do not apply during humid conditions, and do not dry-buff or burnish.

SPECIFICATIONS
Nonvolatile Solids 20 +- 0.6%
Total Active 26%
Resistivity-ASTM D257 10 9 Ohms 2 Max/Cm 2 @
40% Relative Humidity
Static Dissipation 0.02 Second
pH 8.4 - 9.0
Gloss 60 0 80+ @ 3 coats
Color Translucent white
Weight Per Gallon 8.55 - 8.8
Slip Resistance (ASTM) 0.65 Minimum
Stability 1 year minimum
at room temperature
Freeze/Thaw Stability 3 cycles minimum
Drying Time 30 - 45 minutes
Water Resistance Good
Gallon Coverage (Feet 2 ) 1500 - 2000
Removability (Gardner) 75 cycles maximum


SAFETY INFORMATION
Health 1
Flammability 0
Reactivity 0
Personal Protection B


This material is not a hazardous mixture, as defined in 29 CFR 1919, 1200 and M.G.L. c. 111F. Safety glasses and gloves should be worn during application and handling. If ingested drink milk, water, fruit juice, and induce vomiting with oil of ipecac. In the event of eye contact flush area with water for 15 minutes. Contact a Physician. For detailed information consult MSD sheet.