APPLICATION AND MAINTENANCE

For initial application remove any existing finish with #118 Eliminator. Scrub the floor surfaces with a deep cleaning pad (green or brown), or a good quality nylon brush for textured surfaces. Vacuum or mop up the scrubbing solution and rinse the floor with clean water. Optimum results are obtained by applying two or three thin coats of Syn Coat, allowing at least one hour drying time between coats.
For irregular surfaces dilute the finish with equal amounts of water and apply a light coat with a pressurized or airless sprayer.
Regular maintenance will extend the life of Syn-Coat. Sweep, or dry mop with a mop treated with #135 Aqua Treat water-based mop treatment, or vacuum, at least daily or more often as necessary. Follow by damp mopping with #127 Tops Synthetic Neutral Cleaner, or #70 Constant Traction. Avoid using harsh cleaners and oil-based mop treatments. Do not use high speed burnishing machines on these types of flooring.

SPECIFICATIONS
Nonvolatile Solids 12 - 13%
Total Active 15 + 0.5%
pH 8.0 + 0.5
Gloss 80+
Color Light Green
Weight Per Gallon 8.4
Slip Resistance (ASTM) Exceeds 0.5
Stability 1 year minimum
at room temperature
Freeze/Thaw Stability 3 cycles minimum
Drying Time 20 minutes
Water Resistance Excellent
Coverage 1000-1500 Ft.
Removability (Gardner) 70 maximum


SAFETY INFORMATION
Health 1
Flammability 0
Reactivity 0
Personal Protection B


This material is not a hazardous mixture, as defined in 29 CFR 1919, 1200 and M.G.L. c. 111F. Safety glasses and gloves should be worn during application and handling. If ingested, drink milk, water, fruit juice, and induce vomiting with oil of ipecac. In the event of eye contact flush area with water for 15 minutes. Contact a physician. For detailed information consult MSDS sheet.